PURSUIT OS 335 Owner's Manual Page 40

  • Download
  • Add to my manuals
  • Print
  • Page
    / 136
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 39
OS 335
40
HEAD COMPARTMENT PANEL
Holding Tank Macerator
The holding tank overboard discharge macerator switch
panel is located in the head compartment next to the holding
tank monitor. It is a momentary switch that activates the
overboard macerator discharge system for the holding tank.
Refer to the Marine Head System in the Interior Equipment
chapter for additional information on the operation of the
overboard macerator discharge system.
Holding Tank Level
The panel contains the holding tank level indicator that
indicates the level of the holding tank. Refer to the head
system owner's manual for more information on this system.
MISCELLANEOUS ELECTRICAL COMPONENTS
Carbon Monoxide Detector
The breaker supplies current to the carbon monoxide detector. The power indicator on the carbon monoxide
detector should be lit whenever someone is occupying the cabin. If the breaker has tripped, it indicates that
there is a problem with the carbon monoxide detector, the breaker, or the wiring from the breaker panel to
the detector. Always determine the cause of the problem and correct it before resetting the breaker.
CARBON MONOXIDE IS A LETHAL, TOXIC GAS THAT IS COLORLESS AND ODORLESS.
IT IS A DANGEROUS GAS THAT WILL CAUSE DEATH IN CERTAIN LEVELS.
Cabin Lights
Lighting is controlled by a switch located adjacent to the companionway door and by switches on the cabin
lights. The fuse that protects the light circuit is located behind the cabin panel
HALOGEN LIGHTING CONTAINS A FILAMENT BULB THAT GENERATES INTENSE
HEAT, IS PRESSURIZED AND COULD SHATTER IF SCRATCHED OR DAMAGED. PRO-
TECT GLASS HALOGEN-CYCLE BULBS FROM CONTACT WITH LIQUIDS WHEN OPER-
ATING.
12-VOLT RECEPTACLE
Power is provided to the 12-volt accessory receptacle by a breaker located on the breaker panel.
4.5 AC System
The AC system is fed by the shore power outlet or by the optional generator. It is wired totally separate from
the 12-volt DC system and is equipped with an on-board galvanic isolation system. The galvanic isolator is
equipped with a system status monitor. Refer to the galvanic isolator owner's manual. A shore power inlet
breaker is located in the cockpit above the shore power inlet plug. This breaker protects the AC system between
the shore power inlet plug and the main AC panel. All AC current is distributed to the AC accessories through
Head Macerator Switch
Page view 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 ... 135 136

Comments to this Manuals

No comments