13.2 Winterizing
Freshwater System
The entire freshwater system must be completely drained. Disconnect all hoses, check valves,
etc. and blow all the water from the system. Make sure the hot water heater and freshwater tank
are completely drained. Use only very low air pressure when doing this to prevent possible
system damage. Because of the check valve mechanism built in the pump, blowing the lines will
not remove the water from the freshwater pump. Remove the inlet and outlet hoses on the pump.
Turn the pump on and allow it to pump out any remaining water....about a cupful. A
recommended alternative to the above-mentioned procedure is the use of commercially available
non toxic, freshwater system antifreeze. After draining the potable water tank and lines, pour the
antifreeze mixture into the freshwater tank, prime and operate the pump until the mixture flows
from all freshwater faucets. Be sure to open all water faucets, including the freshwater spray head
in the stern bait station sink. Make sure antifreeze has flowed through all of the freshwater drains.
Refer to the Freshwater System chapter for additional information on the freshwater system.
Raw Water System
Completely drain the raw water systems. Disconnect all hoses and blow the water from the
system. Use only very low air pressure when doing this to prevent possible system damage.
Because of the check valve mechanism built in the raw water washdown and livewell pumps,
blowing the lines will not remove the water from that raw water pump. Remove the inlet and
outlet hoses on the pumps. Turn each pump on and allow it to pump out any remaining
water....about a cupful. A recommended alternative to the above-mentioned procedure is the use
of commercially available nontoxic, potable water system antifreeze. If potable water antifreeze
is used, pour the mixture into a pail and put the raw water intake lines into the solution. Run the
pumps one at a time until the antifreeze solution is visible at all raw water faucets and discharge
fittings and drains. Be sure antifreeze has flowed through all of the raw water drains.
Portable Head
The portable head must be properly winterized by following the manufacturers winterizing
instructions in the portable head owners manual.
Marine Toilet
The marine toilet must be properly winterized by following the manufacturers winterizing
instructions in the marine toilet owners manual. Drain the intake and discharge hoses
completely using low air pressure if necessary. The head holding tank and optional macerator
discharge pump must be pumped dry and one gallon of potable water antifreeze poured into the
tank through the deck waste pump out fitting. After the antifreeze has been added to the holding
tank, open the overboard discharge valve and activate the macerator pump until the antifreeze
solution is visible at the discharge thru-hull.
Note: Make sure you follow the marine toilet manufacturer's winterizing instructions
exactly.