5.2 Raw Water Washdown
GENERAL
In the raw water system pump is supplied by hoses connected to a ball valve and thru-hull fitting located in
the bilge accessed under the aft seat.
OPERATION
Always make sure the ball valve is open before attempting to operate the raw water washdown system. The
pump is activated by the washdown switch located in the cockpit. When activated,
the pressure switch will automatically control the pump. As the pressure builds in
the washdown hose, the pump will shut off. When the washdown hose is in use and
the pressure drops, the pump will turn on. Turn the switch off when the washdown
is not in use. The raw water washdown system is equipped with a sea strainer on the
intake side of the pump located in the aft bilge. This should be checked frequently
and cleaned as necessary.
PRIMING THE SYSTEM
Open the ball valve. Open the hose connector for the raw water washdown and
activate the pressure pump. Run the pump until all of the air is purged from the
system. Close the thru-hull ball valve before the boat is hauled from the water will
help to eliminate the air lock in system. It may be necessary to reprime the raw water
system if the system is not used for an extended period.
ALWAYS TURN THE RAW WATER PUMP SWITCH TO THE “OFF” POSITION WHEN LEAV-
ING THE BOAT UNATTENDED.
DO NOT RUN THE HIGH PRESSURE PUMP DRY FOR EXTENDED PERIODS AS DAMAGE TO
THE PUMP WILL RESULT.
5.3 Livewell
Sea water is provided to the livewell by a 12-volt circulating pump. The pump is designed to carry a constant
flow of water to the livewell. The pump is activated by the livewell switch on the helm. An overflow built
into the livewell automatically controls the water level in the livewell. Always turn the pump off at the switch
panel when the livewell is not in use.
To fill the livewell, insert the plug into the drain fitting at the bottom of the livewell. Make sure the ball valve
at the intake thru-hull fitting is open and turn on the livewell pump. When the water level reaches the
overflow, it will begin to circulate. The livewell overflow and drain discharge through a fitting in the
splashwell.
To drain the livewell, turn off the livewell pump and pull out the plug in the drain fitting. When the livewell
has completely drained, use the washdown hose to flush the livewell and drain debris.